Central strength member (FRP rod)
Optical fiber
Gel-filled loose tube
Water-swellable yarns
Inner jacket
Aramid yarns
Jacket
Ripcord
Maximum rated design tension (MRDT), kN | 4 | ||
Crush, kN/cm | 0.22 | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, mm | 12.4 | 14.4 | 17.9 |
Cable weight, kg/km | 113.8 | 148.1 | 229.7 |
Minimum bending radius, mm | 186 | 216 | 269 |
Maximum rated design tension (MRDT), kN | 6 | ||
Crush, kN/cm | 0.22 | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, mm | 12.4 | 14.4 | 17.9 |
Cable weight, kg/km | 115.2 | 149.7 | 230.4 |
Minimum bending radius, mm | 186 | 216 | 269 |
Maximum rated design tension (MRDT), kN | 8 | ||
Crush, kN/cm | 0.22 | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, mm | 12.5 | 14.5 | 17.9 |
Cable weight, kg/km | 117.8 | 151.9 | 232.1 |
Minimum bending radius, mm | 188 | 218 | 269 |
Maximum rated design tension (MRDT), kN | 10 | ||
Crush, kN/cm | 0.22 | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, mm | 12.6 | 14.6 | 18.0 |
Cable weight, kg/km | 120.9 | 154.9 | 235.4 |
Minimum bending radius, mm | 189 | 219 | 270 |
Maximum rated design tension (MRDT), kN | 12 | ||
Crush, kN/cm | 0.22 | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, mm | 12.7 | 14.6 | 18.1 |
Cable weight, kg/km | 123.7 | 157.6 | 238.6 |
Minimum bending radius, mm | 191 | 219 | 272 |
Maximum rated design tension (MRDT), kN | 15 | ||
Crush, kN/cm | 0.22 | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, mm | 12.9 | 14.8 | 18.2 |
Cable weight, kg/km | 127.9 | 161.7 | 243.4 |
Minimum bending radius, mm | 194 | 222 | 273 |
Maximum rated design tension (MRDT), kN | 20 | ||
Crush, kN/cm | 0.22 | ||
Fiber count, up to | 72 (6х12) | 96 (8х12) | 144 (12х12) |
Cable diameter, mm | 13.4 | 15.3 | 18.6 |
Cable weight, kg/km | 136.6 | 170.0 | 252.4 |
Minimum bending radius, mm | 201 | 230 | 279 |
Operating temperature | -50°C ... +70°C |
Installation temperature | -30°C ... +70°C |
Transportation and storage temperature | -50°C ... +70°C |
Minimum bending radius | 15 x cable diameter |
Design life | 25 years |