Direct Buried

Direct Buried MT GSW2 Multi-tube (MT) galvanized steel wires (GSW) double armor double jacket

Application: direct buried installation
Direct Buried MT GSW2 | Emcab
1

Central strength member (FRP rod)

2

Optical fiber

3

Gel-filled loose tube

4

Water-blocking gel

5

Inner jacket

4

Water-blocking gel

6

Double armor of galvanized steel wires

7

Jacket

8

Ripcord

Maximum rated design tension up to 80 kN

Resistance to crushing load 1 kN/сm

Applied in harsh environments with potential mechanical impact: in all ground types, swamps and harsh rivers

Excellent rodent resistance

Maximum rated design tension (MRDT), kN 80
Crush, kN/cm 1
Fiber count, up to 24 48 72 96 144
Cable diameter, mm 19.6 20.0 20.8 21.2 23.2
Cable weight, kg/km 799.1 852.3 904.2 937.1 1190.3
Minimum bending radius, mm 294 300 312 318 348
Start shopping
Operating temperature -40°C ... +70°C
Installation temperature -10°C ... +50°C
Transportation and storage temperature -40°C ... +70°C
Minimum bending radius 15 x cable diameter
Design life 25 years