Optical fiber
Gel-filled stainless steel tube
Armor of steel wires
Jacket
Ripcord
| Maximum rated design tension (MRDT), kN | 7 | |||
| Crush, kN/cm | 1 | |||
| Fiber count, up to | 36 | 48 | 72 | 96 |
| Cable diameter, mm | 9.6 | 9.9 | 10.3 | 10.8 |
| Cable weight, kg/km | 169.5 | 182.1 | 193.0 | 208.7 |
| Minimum bending radius, mm | 144 | 149 | 155 | 162 |
| Maximum rated design tension (MRDT), kN | 10 | |||
| Crush, kN/cm | 1 | |||
| Fiber count, up to | 36 | 48 | 72 | 96 |
| Cable diameter, mm | 10.4 | 10.7 | 11.5 | 11.2 |
| Cable weight, kg/km | 220.8 | 225.6 | 279.0 | 240.4 |
| Minimum bending radius, mm | 156 | 161 | 173 | 168 |
| Transportation and storage temperature | -40°C ... +70°C |
| Installation temperature | -10°C ... +50°C |
| Operating temperature | -40°C ... +70°C |
| Minimum bending radius | 15 x cable diameter |
| Design life | 25 years |