Fire Rated

Fire Rated Dielectric Light Central tube halogen-free jacket design

Application: pulling into underground ducts and sewer pipes
Fire Rated Dielectric Light | Emcab
1

Optical fiber

2

Water-blocking gel

3

Gel-filled loose tube

4

Fiberglass yarns

5

Inner jacket made of halogen-free flame-retardant polymer compound

6

Mica glass tape

4

Fiberglass yarns

7

Halogen-free jacket

8

Ripcord

Remains functional under direct flame for at least 180 minutes

Up to 24 fibers

All-dielectric design

Maximum rated design tension (MRDT), kN 1
Crush, kN/cm 0.2
Fiber count, up to 8 16 24
Cable diameter, mm 8.3 8.9 9.3
Cable weight, kg/km 84.9 97.7 105.9
Minimum bending radius, mm 83 89 93
Maximum rated design tension (MRDT), kN 2
Crush, kN/cm 0.2
Fiber count, up to 8 16 24
Cable diameter, mm 9.3 9.9 10.2
Cable weight, kg/km 106.9 120 128.5
Minimum bending radius, mm 93 99 102
Start shopping
Operating temperature -40°C ... +60°C
Installation temperature -10°C ... +50°C
Transportation and storage temperature -50°C ... +50°C
Minimum bending radius 10 x cable diameter
Design life 25 years